It is doing a nice job:
23cm LNA |
Passband with filtercurve from the ceramic filter, quite good input return loss |
good suppression on 70cm |
Noise figure measurement with HP 346B and Eaton 2075, with 10dB attenuator in front of the LNA its a bit worse abt. 0.5-0.6dB (for unknown reason) |
because the preamp is going to be used for tropo the second stage was removed, the gain is now lower |
its now 22dB @ 80mA |